• My Account
  • Shopping Cart
  • Checkout
Call: 1-403-836-0307
Sigineer Power
  • HOME
  • PRODUCTS
    • Inverter Charger
      • 12V Inverter Chargers
      • 24V Inverter Charger
      • 48V Inverter Charger
      • 110V 120V Single Phase Inverter Charger
      • 120 240V Split Phase Inverter Chargers
      • 1000W – 3000W Inverter Charger
      • 4000W – 6000W Inverter Charger
      • 10kW – 20kW Inverter Charger
      • Tesla Battery Compatible Inverter Charger
      • Three Phase Inverter Charger
    • Solar Inverter
      • ETL Listed Inverter to UL1741 CSA22.2
      • Low Frequency Solar Inverter Duty Transformer
      • Off Grid Solar Inverter without Transformer
    • LiFePO4 Battery
      • 19″ Rack Mount Lithium Battery
      • Lithium Ion Battery Home Powerwall
      • Battery Energy Storage System(BESS)
      • 12v Lithium Ion Battery For Car RV
      • 24V Lithium Ferrophosphate Battery
      • 48V Deep Cycle Lithium Battery
    • Accessories
      • Solar Charge Controller
      • Automatic Transfer Switch
      • Power Inverter Accessories
      • Step Up Down Transformer
  • REVIEWS
  • SUPPORT
    • Warranty & After-Sales Service
    • Document Download
    • Software Download
    • Video Gallery
    • FAQ
    • Customer Care
  • APPLICATIONS
    • Off Grid Renewable Energy
    • Recreational Vehicles
    • Utility Work Vehicles
    • Heavy Duty Work Truck & Fleet
    • Residential Commercial
    • Custom Power Inverter Solutions
  • ABOUT
    • Company Overview
    • Affiliate Program
    • Engineering & Technology
    • Wholesale & Distribution
    • Inverter OEM & ODM
    • Certificates
    • Testimonials
    • Blog
  • CONTACT
  • Click to open the search input field Click to open the search input field Search
  • Menu Menu
  • Shopping Cart Shopping Cart
    0Shopping Cart

Power Saver Mode & Power Saver Off

06/29/2016/0 Comments/in Features, News/by Sigineer Power

The Power Saver Mode is a great feature for transformer based Inverter Charger which usually draws a high current from batteries when left idle.
There are two different working statuses for Sigineer Power’s inverter chargers: “Power On” and “Power Off”.

inverter charger power saver modeWhen power switch is in “Unit Off” position, the inverter is powered off.
When power switch is turned to either of “Power Saver Auto” or “Power Saver Off”, the inverter is powered on.
Power saver function is to dedicated to conserve battery power when AC power is not or little required by the loads.
In this mode, the inverter pulses the AC output looking for an AC load (i.e., electrical appliance). Whenever an AC load (greater than 25 watts) is turned on, the inverter recognizes the need for power and automatically starts inverting and output goes to full voltage. When there is no load (or less than 25 watts) detected, the inverter automatically goes back into search mode to minimize energy consumption from the battery bank.
In “Power saver on” mode, the inverter will draw power mainly in sensing moments, thus the idle consumption is significantly reduced.
The inverter is factory defaulted to detect load for 250ms in every 3 seconds. This power sensing can be customized to “Unit off charging” via the SW3 on DIP switch.
Note: The minimum power of a load to take inverter out of sleep mode (Power Saver On) is 25 Watts.

inverter charger power saver mode

 

 

 

 

 

 

 

 

Note: The minimum power of a load to take inverter out of sleep mode (Power Saver On) is 50 Watts. For split phase models, the power threshold of sleep mode is 50W between Hot1 and Neutral and 200W between Hot 1 and Hot 2. There is no load detection between Hot2 and Neutral.

Note: The minimum power of a load to take inverter out of sleep mode (Power Saver On) is 25 Watts.

 

The whole inverter is designed with extraordinarily low idle power consumption which is approximately 0.8-1.8% of its rated power.

Model | Power Saver Off | Power Saver On
1KW    |          18W             |          7.5W
1.5KW |         25W             |           9W
2KW    |         30W             |           10.0W
3KW    |         60W             |           15.0W
4KW    |         70W             |           20.0W
5KW    |         80W             |           25.0W
6KW    |         90W             |           25.0W
8KW    |         120W           |           30.0W
10KW  |         150W            |           35.0W
12KW  |         180W            |           40.0W
When in the search sense mode, the green power LED will blink and the inverter will make a ticking sound. At full output voltage, the green power LED will light steadily and the inverter will make a steady humming sound. When the inverter is used as an “uninterruptible” power supply the search sense mode function should be defeated.

Exceptions
Some devices when scanned by the load sensor cannot be detected. Small fluorescent lights are the most common example. (Try altering the plug polarity by turning the plug over.) Some computers and sophisticated electronics have power supplies that do not present a load until line voltage is available. When this occurs, each unit waits for the other to begin. To drive these loads either a small companion load must be used to bring the inverter out of its search mode, or the inverter may be programmed to remain at full output voltage.
Note: For split phase models, the power saver functionality is only available on Hot 1.

Under the Battery Priority Mode (SW5 in position “1”), the inverter can be switched between two modes: Power Saver Mode (SW3 in position “1”) and Unit Off Charging Mode (SW3 in position “0”). The power Switch should be in “Power saver on” position all the time for using these functions.
In Power Saver Mode, the inverter is initially in standby mode and sends a pulse to detect the presence of a load every 3 seconds. Each pulse lasts for 250ms. The inverter will remain in standby mode until a load has been detected. Then it will wake up from standby mode and start to invert electricity from the battery bank to supply the load. As this function is under Battery Priority, the inverter will always prefer to invert electricity from battery first even there is a qualified AC input present. Only when the battery voltage is lower than the low voltage alarm point, will the inverter switch to AC input power to charge the battery and supply the load at the same time.
This Power Saver Mode can be changed to Unit Off Charging mode via SW3 by switching it to “0” position. (SW5 still in “1”).

Share this entry
  • Share on Facebook
  • Share on X
  • Share on WhatsApp
  • Share on Pinterest
  • Share on LinkedIn
  • Share on Tumblr
  • Share on Vk
  • Share on Reddit
  • Share by Mail
https://sigineer.com/wp-content/uploads/2023/09/SG-Logo-H70.jpg 0 0 Sigineer Power https://sigineer.com/wp-content/uploads/2023/09/SG-Logo-H70.jpg Sigineer Power2016-06-29 06:59:302017-07-29 01:12:35Power Saver Mode & Power Saver Off
0 replies

Leave a Reply

Want to join the discussion?
Feel free to contribute!

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

This site uses Akismet to reduce spam. Learn how your comment data is processed.

Search Search

CATEGORIES

  • Blog
  • Features
  • Markets
  • News
  • Uncategorized
  • Video

RECENT COMMENTS

    LATEST NEWS

    • UL Listed Inverter Charger
    • AC Coupled Inverter Charger
    • Sigineer Power Launches Off Grid 4KW to 12KW Solar Inverters UL1741 & CSA 22.2 Certified to the United States & Canadian Markets
    • RV INVERTER INSTALLTION INSTRUCTIONS
    • AGS for M series Solar Inverters

    ARCHIVE

    • August 2023
    • May 2022
    • January 2022
    • July 2021
    • April 2021
    • January 2021
    • November 2020
    • February 2020
    • October 2018
    • August 2018
    • October 2017
    • May 2017
    • April 2017
    • March 2017
    • January 2017
    • October 2016
    • September 2016
    • August 2016
    • July 2016
    • June 2016

    TAGS

    power inverter Philippines Sine converter single phase inverter sinusoidal inverter Stackable Power Inverter UL458 inverter ultimate power inverter Whole House Inverter

    COLLECTIONS

    • Inverter Charger
    • Solar Inverter
    • LiFePO4 Battery
    • Solar Charger
    • Accessories

    CUSTOMER CARE

    • PRIVACY POLICY
    • SHIPPING POLICY
    • RETURN & REFUND POLICY
    • TERMS AND CONDITIONS
    • INTELLECTUAL PROPERTY RIGHTS

    CONTACT US

    • Email: info@sigineer.com
    • Phone: +14038360307
    • Skype: sigineer@outlook.com

    ABOUT US

    • INTRODUCTION
    • DISTRIBUTORS
    • TESTIMONIALS
    • FAQ
    • AFFILIATE PROGRAM
    © Copyright 2025 - Sigineer Power
    • Link to Facebook
    • Link to X
    • Link to Flickr
    • Link to Youtube
    Link to: Auto Generator Start (AGS) Link to: Auto Generator Start (AGS) Auto Generator Start (AGS) Link to: Settable Low Battery Alarm & Cutoff Voltages Link to: Settable Low Battery Alarm & Cutoff Voltages Settable Low Battery Alarm & Cutoff Voltages
    Scroll to top Scroll to top Scroll to top