Description
FEATURES
• 24,000 watt low frequency inverter 120/208Vac Three 3 Phase output
• Independently Controlled Pure Sine 3-PH Output & Accepts 100% Unbalanced Load
• Short Transfer Time ( DC to AC, 0ms;AC to DC, 8ms.)
• 3x surge capability for 20 seconds
• AC/Battery Priority Selector For Renewable System
• Remote LCD Panel available
• Battery Temperature Sensor (BTS)
• Automatic Generator Start (AGS)
• 8 Battery Charging Algorithm plus De-sulphation for Flat Batteries
• Multi-step Intelligent Battery Charger w/ PFC (Power Factor Correction)
• Thermally-Controlled AC cooling fan
• Short Circuit/Overload/High Temp Protection
• Will Withstand Vibrating Environment
SPECIFICATIONS
TPH Three Phase Inverter Specification Sheet
Model | TPH 6KW | TPH 18KW | TPH 36KW | TPH 45KW |
---|---|---|---|---|
Continuous Output Power | 6000W | 18000W | 36000W | 45000W |
Surge Rating(20s) | 18000W | 54000W | 108000W | 135000W |
Capable of Starting Electric Motor | 6HP | 18HP | 36HP | 45HP |
Acceptable Unbalanced Load | 100% | |||
Output Waveform | Pure Sine wave/Same as input(Bypass mode) | |||
Nominal Efficiency | 89%(Peak) | |||
Line Mode Efficiency | >95% | |||
Power Factor | 0.9-1.0 | |||
Connection mode | 3-phase 4-wire system+Ground | |||
Output voltage rating | 3AC/N 400V or 208V | |||
Output phase voltage | 120/230VAC | 120/230VAC | 230VAC | 230VAC |
Output Voltage Regulation | ±10% RMS | |||
Output Frequency | 50/60Hz ± 0.3Hz | |||
Short Circuit Protection | Yes, Current Limit Function (Fault after 60ms) | |||
Typical transfer Time | Typical 6-8ms,10ms(Max) | |||
THD | < 3% ( Linear Load ) | |||
Nominal Input Voltage | 48Vdc | |||
Minimum Start Voltage | 42Vdc / 44Vdc | |||
Low Battery Alarm | 42Vdc / 44Vdc | |||
Low Battery Trip | 40V/42V | |||
High Voltage Alarm & Fault | 64Vdc | |||
High DC Input Recovery | 62Vdc | |||
Low Battery Voltage Recover | 52Vdc | |||
Idle Consumption-Search Mode | < 100 W when Power Saver On | |||
Input Phase Voltage Range | Narrow: 96~132VAC / 184~253VAC;Wide: 70~135VAC / 140-270VAC; | |||
Input Frequency Range | Narrow: 47-55±0.3Hz for 50Hz, 57-65±0.3Hz for 60Hz Wide:40-70±0.3Hz for 50Hz/60Hz |
|||
Output Voltage | Same as input | |||
Charger Breaker Rating(220Vac) | 10A | 30A | 60A | 80A |
Charger Breaker Rating(120Vac) | 20A | 60A | N/A | N/A |
Max Charge Rate | 60A | 180A | 360A | 450A |
Power Factor | 0.97 MAX | |||
Over Charge Protection Shutdown | 15.7V for 12Vdc ( *2 for 24Vdc, *4 for 48Vdc) | |||
Charge Voltage | Fast Charge 56-62V | |||
Charge Voltage | Float Charge 53.6-55.2 V | |||
Input Voltage Waveform | Sine wave (Grid or Generator) | |||
Nominal Phase Voltage | 120Vac | 120Vac | 220Vac | 220Vac |
Low Voltage Trip | 70V/96V±4% | 70V/96V±4% | 184V/154V±4% | 184V/154V±4% |
Low Voltage re engage | 75V/100V±4% | 75V/100V±4% | 194V/164V±4% | 194V/164V±4% |
High Voltage Trip | 130V±4% | 130V±4% | 253V/260V±4% | 253V/260V±4% |
High Voltage re engage | 135V±4% | 135V±4% | 243V/270V±4% | 243V/270V±4% |
Max Input AC Voltage | 150VAC | 150VAC | 300VAC | 300VAC |
Nominal Input Frequency | 50Hz or 60Hz (Auto detect) | |||
Low Freq Trip | Narrow: 47±0.3Hz for 50Hz, 57±0.3Hz for 60Hz Wide:40±0.3Hz for 50Hz/60Hz | |||
Low Freq re engage | Narrow: 48±0.3Hz for 50Hz, 58±0.3Hz for 60Hz Wide:42±0.3Hz for 50Hz/60Hz | |||
High Freq Trip | Narrow: 55±0.3Hz for 50Hz, 65±0.3Hz for 60Hz Wide:70±0.3Hz for 50Hz/60Hz | |||
High Freq re engage | Narrow: 54±0.3Hz for 50Hz, 64±0.3Hz for 60Hz Wide:68±0.3Hz for 50Hz/60Hz | |||
Output Short circuit protection | Circuit breaker | |||
Bypass breaker rating(230Vac) | 10A | 30A | 60A | 80A |
Bypass breaker rating(120Vac) | 20A | 60A | N/A | N/A |
Communication methods | RS232/458/CAN | |||
Display | LED+LCD | |||
Unit Size | 804*620*263mm | 804*620*263mm | 650*513*803mm | 760*513*848mm |
Package Size | 980*730*370mm | 980*730*370mm | 800*670*1000mm | 930*670*1100mm |
Net Weight KG | 70 | 120 | 210 | 270 |
Gross Weight KG | 85 | 135 | 240 | 300 |