Low Battery Voltage Shut Down Auto Recovery

The Sigineer Inverter Chargers are designed with Low Battery Voltage Shut Down Auto Recovery After low battery voltage shut off(10V for 12V model or 20V for 24V model or 40V for 48V model), the inverter is able to automatically restore to work after the battery voltage recovers to 13V/26V/52V(with power switch still in “On” position). This […]

AC Input Voltage Range

There are different acceptable AC input voltage range for different kinds of loads. For some relatively sensitive electronic devices, a narrow input range of 184-253VAC (100-135V for 120VAC models) is required to protect them. While for some resistive loads which work in a wide voltage range, the input AC range can be customized to 154-253VAC […]

AC / Battery Priority Mode Switch

      AC/Battery Priority (SW5): The Sigineer Power inverter chargers are designed with AC/Battery priority switch (DIP switch #5). Switch the battery priority selector to Position “0” for AC priority mode, Position”1” for battery priority mode. In AC priority mode, when AC input is present, the battery will be charged first, and the inverter […]

Unit Off Charging

Setting the Sigineer Power Inverter Charger to “Power Saver On” mode and #3 DIP to position “0” will activate the “Unit Off Charging”. “Unit Off Charging” will enable the inverter charger to charge batteries as much as possible while without discharging them. In “Unit Off Charging” mode, the inverter will stay in standby mode without […]

Battery Temperature Sensor

With our Battery Temperature Sensor, you can apply the proper charge voltage for achieving optimum battery performance and longevity. The ideal charge voltage required by batteries changes with battery temperature. The battery temperature sensor allows the charge controller to continuously adjust charge voltage based on actual battery temperature. Temperature compensation of charge voltage assures that […]

Settable Low Battery Alarm & Cutoff Voltages

Siginner Power inverter chargers allows the capability of setting different Low Battery Alarm & Cutoff Voltages according to your specific applications. Deep discharge of the lead acid battery and many others leads to high losses in capacity and early aging. Thus discharging a battery properly according to its characteristics is getting more and more important. In […]

Power Saver Mode & Power Saver Off

The Power Saver Mode is a great feature for transformer based Inverter Charger which usually draws a high current from batteries when left idle. There are two different working statuses for Sigineer Power’s inverter chargers: “Power On” and “Power Off”. When power switch is in “Unit Off” position, the inverter is powered off. When power […]

Auto Generator Start (AGS)

Auto Generator Start (AGS) For PSW7, APC, HP inverters. The Auto Gen Start is a great option to have when your power system have a generator as backup. All Sigineer Power inverter chargers are equipped with the capability to automatically start a generator when battery voltage goes low to alarm and turn the generator off when […]